VENUE INFORMATION SHEET
EXIT Stage Left

156 Eddy Street, San Francisco


Located on the North side of Eddy between Taylor & Mason, a block from the Powell St. BART Station, this is the 49-seat, true black box space of the Eddy St Theatreplex that houses EXIT Theatre and EXIT Café as well. The house is street level and, thus, is wheel-chair accessible.

The Space
See attached Spec Sheet and Ground Plan to check dimension specifics. With curtains in full use, playing space is approximately 20' wide by 16' deep and some wing space is available both Stage Right (SR) & Stage Left (SL). On travelers, the curtains can be manipulated to change these dimensions and expose the bare black wall. Be aware of the 12" column that runs from floor to ceiling, is surrounded by a permanent climbing ladder and is located DSL about 1.5' from the wall. Area lighting will cover to the down stage edge of the column giving you about 2' between "stage" and the first row of audience (at stage level).

Entrances directly to stage can be made USL or DSL by way of the Ante Room. If used, the back curtain indicated above provides a concealed cross to enter SR. If this curtain is opened, no concealed access SR is available.

There is no fly-space, though lightweight items (no more than 25 lbs.) may be dead hung from the light grid above the stage. While the floor is wood, all walls are either sheet rock or lathe and plaster, so attachments are limited. Contact me ASAP to determine feasibility of any hangs or attachments to floor or wall if you wish to explore these options. You may not hang items or compromise the stage in any way without prior approval.

Dressing Room and Storage
Dressing Room Holds 6-7 comfortably and is located off USL. This room can be entered through the Ante Room, the common hallway, or direct from Stage and basically comprises the backstage area. The room itself is fairly simple, providing basics such as prop tables and ample mirror and counter space but no additional amenities. There are no private restrooms or sinks backstage, so performers share general washroom facilities with patrons and EXIT performers. There is no monitor system, but stage noise can be heard in the dressing room. The reverse is LESS true but should be considered by performers spending any time backstage. Note that both load-in and out occur through the same door (from Dressing Room into the common hallway), so consideration for the groups before and after you and attention to handling the 15 minute in/out rule will be crucial.
Storage NONE. Well, that was simple, eh? You need to be able to fully strike all items from the theatre after your performance. If this is an issue for you, please contact me ASAP.

Tech Capacities
Located House Right (HR) of the audience, the booth provides an adequate view of most of the playing space (USL is relatively obscured from view). There is a simple audio monitor (for stage noise) utilized. Windows can be opened for ventilation (a fan is provided) or effect, but this obviously makes sound more of an issue. Access to the booth is through the vestibule, at house level. Be aware, however, that the tech table is on a 2' raised (and somewhat noisy though completely sturdy) platform.


Sound: (1) tape deck, (1) CD player and a 12 channel Behringer mixing board allowing for cross fades plus live mic hook-up or instrument amplification. If you'd like to set up additional sound equipment, the system has some flexibility and you are welcome to do so, but you may be asked to leave it for the duration of the festival to prevent installation mistakes. Again, please contact me well before your tech to deal with feasibility issues. There are 2 speakers dead-hung from the lighting grid at the back of the stage that allow isolation left and right through the amp.
The Fringe provides no projection equipment but can accommodate items that you bring in. There are a couple of shelves on the back of house wall that can support projection or other technical equipment. Clearly, informing me of anything on this front ASAP allows us to work together to determine the best options.
Lights: You will be provided a 12 channel rep plot as follows: [1] lavender back wash (3 Fresnels), [5] area lights (Fresnels focused DR, UR, DC, DL, UL), [1] red wash (2 Lekos), [1] blue wash (2 Lekos), and a choice of [4 ] of 6 specials (L, C, R, Floor Mount, Side L, Side R). The focus and gelling of these instruments will be shown first thing at your tech rehearsal and will not be available for modification. If you are considering bringing in ANY additional lighting equipment, what do you think? Yes, that's right! - please contact me ASAP and we'll discuss feasibility.
The board is a Leprecon MANUAL 2 scene preset. Cues may be cross-faded manually or run as internals. There is an independent channel, add/bump buttons and a chaser. The house lights are on a separate dimmer next to the board.

 

EXIT Stage Left specs

Type: Black Box
Audience Capacity: 49
Standard Playing Dimensions Stage Floor
Width: 20' Wood, no rake
Depth: 18' Height from house floor: 0"
Wing space: 4' x 4' each side
Height (stg-grid): 14'4"
(stg-ceiling): 17'0"
Stage to aud.: 2' (first row of audience on stage floor)
 
Dressing Room/Backstage
Size: 10' x 15'
Capacity: 6-7 people comfy
Access: Through common hall, Ante Room, or direct from Stage
Access to Stage: Door direct to USL, DSL (through Ante Room)
Bathroom: In common hall - shared with audience, EXIT Theatre
Amenities: Mirrors, clothing rack, counter space, prop table, clip lights, fan
 
Booth
Access: Through Ante Room; Size: 8' x 6'; Capacity: 2-3 people max.
Lightboard: 12 channel, 2 scene preset, manual
House lights: Separate dimmer, easy access
Work lights: No control from booth
Monitor: Yes; Booth mic: Yes
Sound system: 8 channel mixing board; (1) cassette players; (1) CD player; 2 channel pro amp
(2) mic. hook-ups, (1) MIC AVAILABLE; (1) instr. hook-up available (1) booth mic
Other: Sliding window; Control of house fans; Limited sight-line for UL action; Fan
Load-in path: Through Dressing Room from common hall
Load out path: Same
Electrical outlets…… Booth: Up to (5)
Stage: (4) SR, (6) US wall
Dressing room: (4)
 
Other:
Shelf on back of house wall optimum for projection equipment
Permanent climbing ladder built around DR column
Work lights controlled solely by switch in Dressing Room
Patrons for both EXIT Theatre & EXIT Stage Left shows queue in common hall
 

Anything not covered here can be handled with a call or e-mail to me at your earliest convenience. Keep in mind that the sooner you contact me, the more likely we'll be able to work together to accommodate your needs.

Thanks for reading and happy Fringing!


Amanda Ortmayer - Production Manager
mail@sffringe.org
phone - 415-440-8825
fax- 415-931-2699
156 Eddy Street
San Franciscio CA, 94102